![]() | Home >> Heating Air Conditioning Portable Air >> Air King Fans,TPI Fans, Soler Palau Fans, Suncourt Fans >> Soler Palau Fans,Bathroom Fans,TD MixedVent,Ventilation,TD-Silent Fans >> S&P Energy Recovery Ventilators ERV-TR, TR70, TR130, TR200 and TR300 >> SPTL S&P percentage timer controller for TR Series ERV |
SPTL S&P percentage timer controller for TR Series ERV
|
SPTL S&P percentage timer controller for TR Series ERV Percent Timer Control-Lighted For use with TR70/TR130/TR200/TR300 Operation The Percent Timer Control-Lighted (SPTL) automatically turns on your TR70, TR130, TR200 or TR300 Total Recovery for All Climates unit every hour, ensuring proper ventilation for your home around-the-clock. When the “Runtime %” light is on, the control is telling your Total Recovery for All Climates unit to operate. Set the control and your ventilator will run once every hour. How long it runs depends on the runtime percentage setting. FOR CONSTANT OPERATION: Press the logo until the 100% light is on. The “Runtime %” light turns on. The TR unit will run continuously. FOR REGULAR OPERATION: Set the control at the percentage that is right for your home. Press the logo until the light for the percent desired is on. See the "Percent Run Time Table" for guidance. You may wish to adjust this percentage to your specific needs. For example, if you have excess humidity in the winter, increase the ventilation percentage. You may also want to decrease the ventilation percentage when the home will be unoccupied for many days, or increase the ventilation percentage during a party. FOR NO REGULAR OPERATION: Press the logo until all lights are off. The control is off. NOTE for TR systems with more than one control: Another control may be causing your ventilator to run. If you wish to keep your ventilator from running, check that none of your controls are calling for unit operation. Installation 1. Install control in a standard 2" x 4" electrical box, with a minimum depth of 1.5", with the two screws provided. 2. Wire Size: 18-22 gauge, no more than 500 feet. Wiring is non-polar. 3. The two wires from the TR should be attached to the ‘C’ and ‘R’ positions on the terminal block on the back of the SPTL Control. 4. Use Lutron Decora™ cover plate to complete installation. Percentage Run Time Table (to achieve 0.35 air changes per hour) As recommended by the American Society of Heating, Refrigeration, and Air Conditioning Engineers *Based on 8’ ceiling height. If ceiling is other than 8’, recalculate house volume based on your ceiling height. Other standards and local codes should be considered when determining the required ventilation rate. | |
![]() | |
|